INSTRUMENTS

Portable photoionization gas analyser COLION-1V

Multiple point gas detection system ESSA

Multiple point gas detection system GOZON

Portable two-detector gas analyzers: COLION-1V-02, COLION-1V-03, COLION-1V-4

Portable chlorine gas analyzer COLION 701

Photoionization fixed gas analyzer COLION-1V-01S

Two-detector fixed gas analyzer COLION-1V-03S

Photoionization fixed gas analyzer with remote samplins COLION-1A-01S


PORTABLE PHOTOIONIZATION GAS ANALYSER COLION-1V

Cat.N WI-1508-101

COLION-1V is designed for monitoring of concentration of VOC and some other toxic compounds in ambient air at workplace.

The photoionization detector (PID) used in COLION-1V allows measuring the concentra­tion a great variety of dangerous compounds in air from low ppm level up to thousands ppm.


Parameter Value
Detection Principles PID (10.6 eV)
Measuring Range 0-2000 mg/m3
Gases All compounds with ionization energies lower then 10.6 eV
Response Time 3 s
Alarm Visual and audible
Gas Sampling Built-in pump, flow-rate 300-500 ml/min
Power Source Rechargeable NiCd battery
Operation Time 8 hours
Temperature - 20 to 45°C
Relative Humidity 0 to 95 %
Size 65 x 205 x 180 mm
Weight 1.3 kg
Approvals ExibIIBT4, Russian National Certificates

Common Compounds Detectable by PID

Get the table with ionization potential in .RTF format (611 Kb)
Open table online



GO BACK


FIXED GAS DETECTION SYSTEMS ESSA

Multiple Point Gas Detection System ESSA

 

Cat.N WI-1508-201

The multiple point gas detection system ESSA consists of controllers and transmitters. It is intended for continuous monitoring of the concentration of ammonia, chlorine, carbon oxide (depending on transmitters used) in the ambient air at the workplace. The controllers have two or three on board relay that will be activated if the gas concentration exceeds the alarm level and can be connected with either 1 or up to 8 transmitters.  Transmitter converts the signal from electrochemical sensor to a 4 to 20 mA. The distance between controller and transmitter can reach 1000 m.


Parameter Gas
Ammonia Chlorine Carbon Oxide
Detection Principle Electrochemical Electrochemical Electrochemical
Measuring Range 0 - 100 mg/m3
0 - 2000 mg/m3
0 - 5 mg/m3
0 - 50 mg/m3
0 - 300 mg/m3
Response Time < 45 s < 45 s < 90 s
Alarm 2 or 3 alarm points, light, relay signal 2 alarm points, light, relay signal 2 alarm points, light, relay signal
Gas Sampling Diffusion Diffusion Diffusion
Transmitter Output 4 - 20 mA 4 - 20 mA 4 - 20 mA
Temperature -35 to +45°C -35 to +45°C -35 to +45°C
Relative Humidity 10 to 95% 10 to 95% 10 to 95%
Approvals Russian National Certificates Russian National Certificates Russian National Certificates


GO BACK


Stand Alone Carbon Oxide Gas Detection System ESSA

 

Cat.N WI-1507-203

Stand Alone carbon oxide gas detection system ESSA is designed for applications where only one fixed point of detection is needed. It is a combination of the transmitter and controller in one unit. The Stand Alone unit is equipped with relays to activate external alarm devices.







Parameter Value
Detection Principle  Electrochemical
Measuring Range 0 - 300 mg/m3
Response Time < 90 s
Alarm 2 alarm points, light, relay signal
Gas Sampling Diffusion
Transmitter Output 4 - 20 mA
Temperature - 35 to 45°C
Relative Humidity 10 to 95%
Approvals Russian National Certificates


GO BACK


FIXED GAS DETECTION SYSTEMS GOZON

Cat.N WI-1508-213

The multiple point gas detection system GOZON consists of controllers and transmitters. It is intended for continuous monitoring of the concentration of ozone in the ambient air at the workplace. The controllers have two or three on board relay that will be activated if the gas concentration exceeds the alarm level and can be connected with either 1 or up to 8 transmitters. Transmitter converts the signal from electrochemical sensor to a 4 to 20 mA. The distance between controller and transmitter can reach 1000 m.


Parameter Value
Detection Principle  Electrochemical
Measuring Range 0 - 1 mg/m3
Response Time < 45 s
Alarm 2 alarm points, light, relay signal
Gas Sampling Diffusion
Transmitter Output 4 - 20 mA
Temperature - 35 to 45°C
Relative Humidity 10 to 95%
Approvals Russian National Certificates


GO BACK


PORTABLE TWO-DETECTOR GAS ANALYZERS COLION-1V-02, COLION-1V-03, COLION-1V-4

Cat.N WI-1508-102, WI-1508-103, WI-1508-104

Comprise two detectors: PID to measure air contamination with VOC and some other toxic compounds and electrochemical one to measure selectively carbon oxide (COLION-1V-02), hydrogen sulfide (COLION-1V-03), nitrogen dioxide (COLION-1V-04)


Parameter COLION-1V-02 COLION-1V-03 COLION-1V-04
Detection Principles PID (10.6 eV) and Electrochemical (CO) PID (10.6 eV) and Electrochemical (H2S) PID (10.6 eV) and Electrochemical (NO2)
Measuring Range 0 - 2000 mg/m3 (PID)
0 - 300 mg/m3 (CO)
0 - 2000 mg/m3 (PID)
0 - 30 mg/m3 (H2S)
0 - 2000 mg/m3 (PID)
0 - 10 mg/m3 (NO2)
Gases All compounds with ionization energies lower then 10.6 eV (PID), ñarbon oxide (electrochemical) All compounds with ionization energies lower then 10.6 eV (PID), hydrogen sulfide (electrochemical) All compounds with ionization energies lower then 10.6 eV (PID), nitrogen dioxide (electrochemical)
Response Time 3 s (PID), < 90 s (CO) 3 s (PID), < 90 s (H2S) 3 s (PID), < 90 s (NO2)
Alarm Visual and audible Visual and audible Visual and audible
Gas Sampling Built-in pump, flow-rate 300 - 500 ml/min Built-in pump, flow-rate 300 - 500 ml/min Built-in pump, flow-rate 300 - 500 ml/min
Power Source Rechargeable NiCd battery Rechargeable NiCd battery Rechargeable NiCd battery
Operation Time 8 hours 8 hours 8 hours
Temperature - 20 to 45°C - 20 to 45°C - 20 to 45°C
Relative Humidity 10 to 90 % 10 to 90 % 10 to 90 %
Size 65 x 205 x 180 mm 65 x 205 x 180 mm 65 x 205 x 180 mm
Weight 1.3 kg 1.3 kg 1.3 kg
Approvals Russian National Certificates Russian National Certificates Russian National Certificates

Common Compounds Detectable by PID

Get the table with ionization potential in .RTF format (611 Kb)
Open table online



GO BACK


PORTABLE CHLORINE GAS ANALYZER

Cat.N WI-1508-107

COLION-701 is intended to measure chlorine in air.






Parameter Value
Detection Principle  Electrochemical
Measuring Range 0 - 20 mg/m3
Response Time < 45 s
Alarm Visual and audible
Gas Sampling Built-in pump, 300 - 500 ml/min
Power Source Rechargeable NiCd battery
Operation time 6 hours continuous operation
Temperature - 20 to 45°C
Relative Humidity 30 to 95%
Size 65 x 205 x 180 mm
Weight 1.3 kg


GO BACK


PHOTOIONIZATION FIXED GAS ANALYZER
COLION-1V-01S

Cat.N WI-1508-112

COLION-1V-01S is designed for continuous monitoring of concentration of VOC and some other toxic compounds in ambient air at workplace. COLION-1V-01S is equipped with relays that will be activated if the gas concentration exceeds the alarm level. The photoionization detector used in COLION-1V-01S allows measuring the concentration of a great variety of dangerous compounds in air from low ppm level up to thousands ppm.


Parameter Value
Detection Principle  Photoionization
Lamp energy 10.6 eV
Measuring Range 0-2000 mg/m3
Response Time < 3 s
Alarm 2 alarm points, light, relay signal
Gas Sampling Built-in pump, up to 0,5 l/min
Output Indication of the concentration measured, mg/m3, relays
Operation time 6 hours continuous operation
Temperature - 20 to 45°C
Relative Humidity 30 to 95%
Power Supply 220 V, 50 Hz
Size 220 x 220 x 110 mm
Approvals ExibIIBT4, Russian National Certificates

Common Compounds Detectable by PID

Get the table with ionization potential in .RTF format (611 Kb)
Open table online



GO BACK


TWO-DETECTOR FIXED GAS ANALYZER
COLION-1V-03S

 

Cat.N WI-1508-113

COLION-1V-03S is designed for continuous monitoring of concentration of VOC and some other toxic compounds and separately hydrogen separately sulfide in ambient air at workplace. COLION-1V-03S is equipped with relays that will be activated if the gas concentration measured by any detector or both exceeds the alarm level.

The photoionization detector used in COLION-1V-03S allows measuring the concentration of a great variety of dangerous compounds in air from low ppm level up to thousands ppm. To measure hydrogen sulfide electrochemical sensor is used.


Parameter Value
Detection Principle  Photoionization
Electrochemical
Lamp energy 10.6 eV
Measuring Range 0-2000 mg/m3
0 - 30 mg/m3 (H2S)
Response Time < 5 s (PID)
< 90 (H2S)s
Alarm 2 alarm points, light, relay signal
Gas Sampling Built-in pump, up to 500 ml/min
Output Indication of the concentration measured, mg/m3, relays, RS-232
Temperature - 20 to 45°C
Relative Humidity 30 to 95%
Power Supply 220 V, 50 Hz
Size 220 x 220 x 110 mm
Approvals ExibIIBT4, Russian National Certificates

Common Compounds Detectable by PID

Get table with ionization potential in .RTF format (611 Kb)
Open table online



GO BACK


PHOTOIONIZATION FIXED GAS ANALYZER
COLION-1A-01S WITH REMOTE SAMPLING

Cat.N WI-1508-111

COLION-1A-01S is designed for continuous monitoring of concentration of VOC and some other toxic compounds in ambient air at workplace. COLION-1A-01S incorporates a powerful pump for remote sampling of air monitored from points up to 100 m away from the instrument. The instrument allows to monitor air contamination at extremely low temperatures and at areas where compounds with low self-ignition temperature present. COLION-1A-01S is equipped with relays that will be activated if the gas concentration exceeds the alarm level.

The photoionization detector used in COLION-1A-01S allows measuring the concentration of a great variety of dangerous compounds in air from low ppm level up to thousands ppm.


Parameter Value
Detection Principle  Photoionization
Lamp energy 10.6 eV
Measuring Range 0-2000 mg/m3
0 - 10000 mg/m3
Response Time < 5 s (when sampling line is of 1 m)
Alarm 2 alarm points, light, relay signal
Gas Sampling Built-in pump, up to 2 l/min
Output Indication of the concentration measured, mg/m3, relays, 4 - 20 mA, RS-232
Temperature, area monitored - 60 to 45°C
Temperature, point of instrument location 5 to 45°C
Relative Humidity 30 to 95%
Power Supply 220 V, 50 Hz
Size 450 x 230 x 110 mm
Approvals Russian National Certificates

Common Compounds Detectable by PID

Get table with ionization potential in .RTF format (611 Kb)
Open table online



GO BACK