OEM PRODUCTSPhotoionization detector PHD-2 Non-radioactive ionization source PHOTOIONIZATION DETECTOR PHD-2
Cat.N WO-1508-001 Photoionization detector PHD-2 is designed for using in portable gas analyzers and fixed point gas detection systems. PHD-2 provides sensitive, accurate and reliable measurement of wide variety of dangerous contaminants. PHD-2 consists of photoionization VUV-lamp and ionization cell. PHD-2 only and PHD-2 with support electronics are both available.
Features
Common Compounds Detectable by PID Get the table with ionization potential in .RTF format (611 Kb) NON-RADIOACTIVE IONIZATION SOURCE FOR ANALYTICAL INSTRUMENTATIONCat.N WO-1506-011
Main features
Non-radioactive ionization source (NRIS) is intended for using in electron-capture GC detectors, Mass Spectrometers, IMS and other instruments. NRIS is a micro X-ray source that consists of a small evacuated glass tube having heated tungsten cathode and a special window that is used as anode. The electrons, emitted by a heated cathode, are accelerated by the voltage applied to electrodes and get absorbed in the window, causing very soft X-ray radiation, that is used to ionized the substances to be detected. The window is made of mica having thickness 5 – 7 mm and coated with metal film with thickness up to 0,3 mm. The NRIS was proved with Ion Mobility Spectrometer (IMS) and has shown absolutely the same analytical performance as Ni IMS with activity of the source of 555 MBq or even a better one. HIGH-TEMPERATURE PHOTOIONIZATION GC DETECTOR CHROMDET-1020
Cat.N WO-1508-002 The photoionization detector (PID) is used to analyze a wide variety of compounds. PID has high sensitivity to the majority of aliphtics (except C1 - C4), aromatics, ketones, aldehydes, alcohols, amines, organic sulfur compounds. It can be also used to detect some inorganics: arsine, ammonia, hydrogen sulfide and others. At the same time PID does not respond to many commonly used solvents such as methanol and acetonitrile. PID CHROMDET 1020 can be mounted on any laboratory or portable GC. Detector has original design patented in Russia. The main feature of construction is the absence of seal between the lamp window and ionization chamber. Only corund non-porosity ceramic is applied for insulation. PID CHROMDET 1020 needs only carrier-gas for operation and can be used both with packed and capillary columns. This provides the following advantages over the conventional PID:
PID CHROMDET 1020 can be connected to any electrometer with total scale of 2 x 10 **(-12) A. The lamp operation as well the ionization chamber polarizing voltage are available by special power supply board that comes with PID. Power consumption is no more then 0.3 W. The only substances ionized by lamp radiation give responses. PID CHROMDET 1020 can be supplied with the lamps emitting photons of different energies. Because of high selectivity PID CHROMDET 1020 can be used for substance identification. EXAMPLES OF PID CHROMDET - 1020 APPLICATIONS PID CROMDET 1020 with 10.6 eV lamp. SE-30 fused silica capillary column, 30 m x 0.53 mm ID. Col. Temp.: 50 C for 10 min., then to 200 C at 5 C/min., 15 min. final hold, Inj. Temp.: 290 C, Det. Temp.: 270 C, Flow Rate: 4 ml/min., Splitless. ![]() Cigarette "Marlboro Lights" smoke in air
![]() Sample of the working place air
PHOTOIONIZATION LAMPS
FEATURES ·
DC and RF excited lamps ·
Krypton, Xenon filling ·
RF lamp diameter from 6 mm ·
Exceptionally high stability and output ·
Magnesium fluoride, sapphire windows ·
Operation temperature up to 350 °Ñ ·
RF lamp custom design capability without price change ·
Low ignition voltage for DC lamps ·
Unlimited shelf life · Long life
Electrodeless RF VUV-lamps
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
©